The phase balance test shall be performed in accordance with figure 6. When any difference from the
mean reading (approximately -0.35 volts) on the VTVM is greater than 0.05 volts, the mixer fails this
test.
FIGURE 6. Phase balance test setup for PIN M28837/1-01 and M28837/1-02.