TABLE I. Electrical characteristics - Continued.
RF and LO 2/
Conversion
Desensitization
Relative
Dash
VSWR (maximum)
Third order, two tone
maximum
compression
(maximum)
dc
no.
intermodulation
power
(maximum)
polarity
input
3/
LO
IF
RF
dBm
Frequencies
(rms)
04N
200 mW
1.0 dB @
1.0 dB @
Positive
2.8:1
3.0:1
3.0:1
+18
fLO: 1,150 MHz
04S
PR +7 dBm
PR2 +5 dBm
fR1: 500 MHz @ -5 dBm
fR2: 505 MHz @ -5 dBm
1/ Unless otherwise specified, TV is the test value of the LO power for the electrical characteristics.
2/ These values are for +25°C and are derated linearly to +100°C.
3/ With two in-phase signals applied to the LO and RF ports.
4/ Input intercept points.