TABLE I. Electrical characteristics - Continued.
Dash
RF and LO 2/
Conversion
Desensitization
Relative
VSWR (maximum)
Third order, two tone
no.
maximum
compression
(maximum)
dc
intermodulation
power
(maximum)
polarity
input
3/
LO
IF
RF
dBm
Frequencies
(rms)
01N
200 mW
1.0 dB @
fLO: 600 MHz
1.0 dB @
Positive
2.0:1
---
2.0:1
+7
01S
PR -8 dBm
4/
fR1: 500 MHz @ - 20 dBm
PR2 -10 dBm
fR2: 505 MHz @ -20 dBm
02N
500 mW
1.0 dB @
fL0: 15 MHz @ +23 dBm
1.0 dB @
Negative
2.5:1
2.0:1
3.5:1
+25
02S
PR +20 dBm
4/
fR1: 10 MHz @ 0 dBm
PR2 +18 dBm
fR2: 11 MHz @ 0 dBm
+23
fL0: 400 MHz @ +23 dBm
fR1: 1000 MHz @ 0 dBm
fR2: 900 MHz @ 0 dBm
03N
200 mW
1.0 dB @
fL0: 15 MHz
1.0 dB @
Positive
2.1:1
2.8:1
3.0:1
+12
03S
PR 0 dBm
4/
fR1: 10 MHz @ -10 dBm
PR2 -2 dBm
fR2: 11 MHz @ -10 dBm
+10
fL0: 1500 MHz
fR1: 1400 MHz @ -10 dBm
fR2: 1410 MHz @ -10 dBm
See footnotes at end of table.